{"id":1228,"date":"2025-06-24T11:24:43","date_gmt":"2025-06-24T03:24:43","guid":{"rendered":"https:\/\/www.puncturetest.com\/?page_id=1228"},"modified":"2025-07-03T15:43:22","modified_gmt":"2025-07-03T07:43:22","slug":"iso-11040-4","status":"publish","type":"page","link":"https:\/\/www.puncturetest.com\/fr\/standards\/iso-11040-4\/","title":{"rendered":"ISO 11040-4"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1228\" class=\"elementor elementor-1228\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c60fdbb e-flex e-con-boxed e-con e-parent\" data-id=\"c60fdbb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-db6fcba e-con-full e-flex e-con e-child\" data-id=\"db6fcba\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9d1f798 e-con-full e-flex e-con e-child\" data-id=\"9d1f798\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-8cc5a79 e-con-full e-flex e-con e-child\" data-id=\"8cc5a79\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6b67d4 elementor-widget elementor-widget-heading\" data-id=\"b6b67d4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4<br><small>Test de p\u00e9n\u00e9tration \u00e0 l'aiguille<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69f526a elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"69f526a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"201\">Garantir la performance et la s\u00e9curit\u00e9 des seringues pr\u00e9remplies est essentiel dans les applications m\u00e9dicales et pharmaceutiques. <strong data-start=\"521\" data-end=\"536\">ISO 11040-4<\/strong> d\u00e9crit les sp\u00e9cifications essentielles pour <strong data-start=\"579\" data-end=\"667\">f\u00fbts en verre pour produits injectables et seringues sous-assembl\u00e9es st\u00e9rilis\u00e9es pr\u00eates \u00e0 \u00eatre remplies<\/strong>. L'une des \u00e9valuations critiques de la qualit\u00e9 dans le cadre de cette norme est l'\u00e9valuation de la qualit\u00e9 de l'eau. <strong data-start=\"736\" data-end=\"770\">m\u00e9thode d'essai de p\u00e9n\u00e9tration de l'aiguille<\/strong>qui \u00e9value la facilit\u00e9 avec laquelle une aiguille de seringue p\u00e9n\u00e8tre dans un mat\u00e9riau standard.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eff30d4 elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"eff30d4\" data-element_type=\"widget\" data-settings=\"{&quot;button_width&quot;:&quot;25&quot;,&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" action=\"\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"1228\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"eff30d4\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"Puncture Test\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tNom\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Nom\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-field_26b0101 elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-field_26b0101\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tEntreprise\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[field_26b0101]\" id=\"form-field-field_26b0101\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Entreprise\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tCourriel\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Courriel\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tMessage\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Message\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-recaptcha elementor-field-group elementor-column elementor-field-group-field_50f0fd6 elementor-col-100\">\n\t\t\t\t\t<div class=\"elementor-field\" id=\"form-field-field_50f0fd6\"><div class=\"elementor-g-recaptcha\" data-sitekey=\"6LcO3HUrAAAAAKhAi3KjswdM4-_7i5zKd1s5FO2N\" data-type=\"v2_checkbox\" data-theme=\"light\" data-size=\"normal\"><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-25 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyer<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"fr\"\/><\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-163fe1b e-con-full e-flex e-con e-child\" data-id=\"163fe1b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f2b60d e-flex e-con-boxed e-con e-parent\" data-id=\"3f2b60d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c5f6d2 elementor-widget elementor-widget-heading\" data-id=\"7c5f6d2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qu'est-ce que la norme ISO 11040-4 et pourquoi est-elle importante ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6126588 elementor-widget elementor-widget-text-editor\" data-id=\"6126588\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1111\" data-end=\"1465\"><strong data-start=\"1111\" data-end=\"1126\">ISO 11040-4<\/strong> est une norme mondialement reconnue de la s\u00e9rie ISO 11040 qui traite sp\u00e9cifiquement des questions suivantes <strong data-start=\"1213\" data-end=\"1246\">f\u00fbts en verre pour produits injectables<\/strong> et <strong data-start=\"1251\" data-end=\"1288\">seringues st\u00e9rilis\u00e9es pr\u00e9-assembl\u00e9es<\/strong> destin\u00e9s au remplissage aseptique. Il garantit que ces composants r\u00e9pondent \u00e0 des crit\u00e8res dimensionnels et fonctionnels stricts afin de pr\u00e9server la st\u00e9rilit\u00e9 du produit, la compatibilit\u00e9 et la s\u00e9curit\u00e9 du patient.<\/p><p data-start=\"1467\" data-end=\"1763\">Une partie importante de cette norme est la <strong data-start=\"1510\" data-end=\"1537\">test de p\u00e9n\u00e9tration \u00e0 l'aiguille<\/strong>qui v\u00e9rifie l'existence de la <strong data-start=\"1558\" data-end=\"1584\">performance m\u00e9canique<\/strong> de l'aiguille lors de son utilisation. La facilit\u00e9 avec laquelle une aiguille peut percer un substrat se refl\u00e8te sur son <strong data-start=\"1681\" data-end=\"1731\">tranchant, qualit\u00e9 des mat\u00e9riaux, traitement de surface<\/strong>et la coh\u00e9rence de la fabrication.<\/p><p data-start=\"1765\" data-end=\"1794\">Ces tests sont essentiels pour<\/p><ul><li data-start=\"1798\" data-end=\"1858\">Assurer des injections en douceur avec un minimum d'inconfort pour le patient<\/li><li data-start=\"1861\" data-end=\"1900\">Pr\u00e9vention de la rupture ou de la flexion de l'aiguille<\/li><li data-start=\"1903\" data-end=\"1956\">Garantir la compatibilit\u00e9 avec les mat\u00e9riaux d'emballage<\/li><li data-start=\"1959\" data-end=\"2008\">Confirmation de la conformit\u00e9 en vue d'une soumission r\u00e9glementaire<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-580df19 e-flex e-con-boxed e-con e-parent\" data-id=\"580df19\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8262e73 elementor-widget elementor-widget-heading\" data-id=\"8262e73\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Explication de la m\u00e9thode du test de p\u00e9n\u00e9tration \u00e0 l'aiguille<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c71437 elementor-widget elementor-widget-text-editor\" data-id=\"7c71437\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2061\" data-end=\"2365\">Le <strong data-start=\"2065\" data-end=\"2099\">m\u00e9thode d'essai de p\u00e9n\u00e9tration de l'aiguille<\/strong>comme indiqu\u00e9 dans l'annexe F de la norme ISO 11040-4, \u00e9value la qualit\u00e9 de l'air et de l'eau. <strong data-start=\"2153\" data-end=\"2222\">force requise pour qu'une aiguille de seringue perce une feuille d'essai d\u00e9finie<\/strong>. Cette proc\u00e9dure est d\u00e9riv\u00e9e de la norme DIN 13097-4 et est r\u00e9f\u00e9renc\u00e9e dans le document suivant <a href=\"https:\/\/www.puncturetest.com\/fr\/standards\/iso-7864-needle-penetration-drag-force-test\/\"><strong data-start=\"2288\" data-end=\"2300\">ISO 7864<\/strong><\/a>Une autre norme importante concerne les aiguilles hypodermiques st\u00e9riles.<\/p><p data-start=\"2367\" data-end=\"2404\">Les principaux \u00e9l\u00e9ments de la m\u00e9thode sont les suivants<\/p><ul><li data-start=\"2408\" data-end=\"2534\"><strong data-start=\"2408\" data-end=\"2426\">Appareil de test<\/strong>: A <strong data-start=\"2430\" data-end=\"2474\">testeur universel de traction et de compression<\/strong> avec une force allant jusqu'\u00e0 10 N et une vitesse de 20 \u00e0 200 mm\/min.<\/li><li data-start=\"2537\" data-end=\"2612\"><strong data-start=\"2537\" data-end=\"2554\">Taux d'\u00e9chantillonnage<\/strong>: 500 Hz est recommand\u00e9 pour une d\u00e9tection pr\u00e9cise des pics de force.<\/li><li data-start=\"2615\" data-end=\"2685\"><strong data-start=\"2615\" data-end=\"2632\">Porte-aiguille<\/strong>: Assure un alignement vertical pour une p\u00e9n\u00e9tration pr\u00e9cise.<\/li><li data-start=\"2688\" data-end=\"2779\"><strong data-start=\"2688\" data-end=\"2701\">Feuille d'essai<\/strong>: Le mat\u00e9riau et l'\u00e9paisseur sont \u00e0 convenir entre le fabricant et le client.<\/li><li data-start=\"2782\" data-end=\"2861\"><strong data-start=\"2782\" data-end=\"2800\">\u00c9chantillons d'aiguilles<\/strong>: Peut \u00eatre silicon\u00e9 ou non trait\u00e9, en fonction de l'utilisation pr\u00e9vue.<\/li><li data-start=\"2864\" data-end=\"2992\"><strong data-start=\"2864\" data-end=\"2883\">Collecte de donn\u00e9es<\/strong>: A <strong data-start=\"2887\" data-end=\"2919\">courbe de la force en fonction du d\u00e9placement<\/strong> est g\u00e9n\u00e9r\u00e9 pour chaque test, mesurant <strong data-start=\"2958\" data-end=\"2972\">force maximale<\/strong> et <strong data-start=\"2977\" data-end=\"2991\">force de tra\u00een\u00e9e<\/strong>.<\/li><\/ul><p data-start=\"2994\" data-end=\"3141\">La m\u00e9thode garantit que le <strong data-start=\"3025\" data-end=\"3068\">la nettet\u00e9 de l'aiguille et l'uniformit\u00e9 du rev\u00eatement<\/strong> se situent dans des param\u00e8tres acceptables, ce qui garantit une performance fiable de la seringue.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a9693b2 e-flex e-con-boxed e-con e-parent\" data-id=\"a9693b2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b44c843 elementor-widget elementor-widget-heading\" data-id=\"b44c843\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Meilleures pratiques pour le test de l'aiguille de la seringue<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e38b53 elementor-widget elementor-widget-text-editor\" data-id=\"3e38b53\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3188\" data-end=\"3329\">Lors de la r\u00e9alisation d'un <strong data-start=\"3206\" data-end=\"3229\">test de l'aiguille de la seringue<\/strong>Il est donc essentiel de suivre les lignes directrices de l'ISO tout en optimisant le processus pour garantir la coh\u00e9rence et la pr\u00e9cision :<\/p><ol><li><strong data-start=\"3334\" data-end=\"3362\">Utiliser des substrats valid\u00e9s<\/strong>: Tels que <strong data-start=\"3372\" data-end=\"3388\">caoutchouc latex<\/strong>, <strong data-start=\"3390\" data-end=\"3406\">polyur\u00e9thane<\/strong>ou <strong data-start=\"3411\" data-end=\"3427\">poly\u00e9thyl\u00e8ne<\/strong> qui imitent les conditions de la peau ou de l'emballage.<\/li><li><strong data-start=\"3472\" data-end=\"3507\">Contr\u00f4ler les variables environnementales<\/strong>: Maintenir la coh\u00e9rence <strong data-start=\"3529\" data-end=\"3557\">temp\u00e9rature et humidit\u00e9<\/strong> pendant les essais.<\/li><li><strong data-start=\"3577\" data-end=\"3599\">\u00c9viter la r\u00e9utilisation des \u00e9chantillons<\/strong>: Chaque essai doit \u00eatre effectu\u00e9 sur une nouvelle section de feuille ou de substrat.<\/li><li><strong data-start=\"3661\" data-end=\"3683\">Assurer l'\u00e9talonnage<\/strong>: La machine d'essai doit \u00eatre \u00e9talonn\u00e9e r\u00e9guli\u00e8rement \u00e0 l'aide d'\u00e9talons tra\u00e7ables.<\/li><li><strong data-start=\"3765\" data-end=\"3788\">Documenter minutieusement<\/strong>: Inclure les sp\u00e9cifications du film, la vitesse d'essai, le nombre d'\u00e9chantillons et toutes les courbes de force dans le rapport d'essai.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a6df764 e-flex e-con-boxed e-con e-parent\" data-id=\"a6df764\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15bd215 elementor-widget elementor-widget-heading\" data-id=\"15bd215\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.puncturetest.com\/fr\/tissue-paper-ball-burst-strength-test\/\">\u00c9quipement de test de p\u00e9n\u00e9tration d'aiguille pour la conformit\u00e9 \u00e0 la norme ISO 11040-4<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e5f91e3 e-con-full e-flex e-con e-child\" data-id=\"e5f91e3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-44c6d75 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"44c6d75\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3963\" data-end=\"4156\">Pour les laboratoires et les fabricants qui ont besoin de r\u00e9aliser des tests de p\u00e9n\u00e9tration d'aiguilles conform\u00e9ment \u00e0 la norme ISO 11040-4, <strong data-start=\"4060\" data-end=\"4114\">Testeur de p\u00e9n\u00e9tration d'aiguille NPT-01 de Cell Instruments<\/strong> est une solution fiable et performante.<\/p><p data-start=\"4158\" data-end=\"4197\">Principales caract\u00e9ristiques de la <strong data-start=\"4178\" data-end=\"4188\">NPT-01<\/strong> inclure :<\/p><ul><li>Capteurs de force de haute pr\u00e9cision avec une pr\u00e9cision de \u00b10,5%<\/li><li>Vitesses d'essai r\u00e9glables de 20 mm\/min \u00e0 200 mm\/min<\/li><li>En temps r\u00e9el <strong data-start=\"4320\" data-end=\"4349\">les courbes force-d\u00e9placement<\/strong> avec des donn\u00e9es exportables<\/li><li>Porte-aiguilles et pinces \u00e0 feuille personnalisables<\/li><li>Compatible avec diff\u00e9rentes tailles de seringues et diff\u00e9rents calibres d'aiguilles<\/li><\/ul><p data-start=\"4482\" data-end=\"4726\">L'utilisation de la <strong data-start=\"4492\" data-end=\"4502\">NPT-01<\/strong> rationalise la conformit\u00e9 aux normes ISO 11040-4 et ISO 7864 tout en r\u00e9duisant la variabilit\u00e9 et en am\u00e9liorant l'int\u00e9grit\u00e9 des donn\u00e9es. Il est particuli\u00e8rement bien adapt\u00e9 pour <strong data-start=\"4648\" data-end=\"4684\">Laboratoires de R&amp;D, d\u00e9partements de contr\u00f4le de la qualit\u00e9<\/strong>et <strong data-start=\"4690\" data-end=\"4725\">processus de validation r\u00e9glementaire<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5f0632 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"e5f0632\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.puncturetest.com\/fr\/penetrability-tester-needle-penetration-test-method\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"400\" src=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\" class=\"attachment-full size-full wp-image-1230\" alt=\"ISO 11040-4 M\u00e9thode d&#039;essai de p\u00e9n\u00e9tration \u00e0 l&#039;aiguille\" srcset=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp 500w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method-300x240.webp 300w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method-15x12.webp 15w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6821011 e-con-full e-flex e-con e-parent\" data-id=\"6821011\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-665057d elementor-cta--skin-classic elementor-animated-content elementor-bg-transform elementor-bg-transform-zoom-in elementor-widget elementor-widget-call-to-action\" data-id=\"665057d\" data-element_type=\"widget\" data-widget_type=\"call-to-action.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-cta\">\n\t\t\t\t\t<div class=\"elementor-cta__bg-wrapper\">\n\t\t\t\t<div class=\"elementor-cta__bg elementor-bg\" style=\"background-image: url(https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/02\/Elastomeric-Closures-Penetrability-Test-1024x256.webp);\" role=\"img\" aria-label=\"Test de p\u00e9n\u00e9trabilit\u00e9 des fermetures \u00e9lastom\u00e8res\"><\/div>\n\t\t\t\t<div class=\"elementor-cta__bg-overlay\"><\/div>\n\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-cta__content\">\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h2 class=\"elementor-cta__title elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tAssurez d\u00e8s aujourd'hui la conformit\u00e9 de vos aiguilles de seringues\t\t\t\t\t<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__description elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tComprendre et appliquer la <b>ISO 11040-4 M\u00e9thode d'essai de p\u00e9n\u00e9tration de l'aiguille<\/b> est vitale pour tout fabricant produisant des <b>seringues pr\u00e9remplies ou aiguilles hypodermiques<\/b>. La norme fournit des lignes directrices claires pour l'\u00e9quipement, la proc\u00e9dure de test et les rapports afin de garantir l'int\u00e9grit\u00e9 de l'aiguille et la s\u00e9curit\u00e9 du patient. En int\u00e9grant <b>\u00e9quipement fiable de test d'aiguille de seringue<\/b> comme le <b>Puncturetest.com NPT-01<\/b>Les entreprises peuvent ainsi rationaliser la conformit\u00e9, r\u00e9duire les risques et am\u00e9liorer la qualit\u00e9 de leurs produits.\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__button-wrapper elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t<a class=\"elementor-cta__button elementor-button elementor-size-\" href=\"https:\/\/www.puncturetest.com\/fr\/contact\/\">\n\t\t\t\t\t\tCliquez ici\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 11040-4Needle Penetration Test Ensuring the performance and safety of prefilled syringes is vital in medical and pharmaceutical applications. ISO 11040-4 outlines the essential specifications for glass barrels for injectables and sterilized subassembled syringes ready for filling. One of the critical quality assessments under this standard is the needle penetration test method, which evaluates how [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"parent":974,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1228","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test<\/title>\n<meta name=\"description\" content=\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.puncturetest.com\/fr\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test\" \/>\n<meta property=\"og:description\" content=\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.puncturetest.com\/fr\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:site_name\" content=\"Puncture Test\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-03T07:43:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\",\"url\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\",\"name\":\"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test\",\"isPartOf\":{\"@id\":\"https:\/\/www.puncturetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\",\"datePublished\":\"2025-06-24T03:24:43+00:00\",\"dateModified\":\"2025-07-03T07:43:22+00:00\",\"description\":\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.puncturetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Puncture Testing Standards\",\"item\":\"https:\/\/www.puncturetest.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 11040-4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.puncturetest.com\/#website\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"name\":\"Softgel Test\",\"description\":\"Puncture and Penetrabiity Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.puncturetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.puncturetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.puncturetest.com\/#organization\",\"name\":\"Softgel Test\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"width\":836,\"height\":238,\"caption\":\"Softgel Test\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 11040-4 M\u00e9thode d'essai de p\u00e9n\u00e9tration d'aiguille - Essai d'aiguille de seringue","description":"M\u00e9thode de test de p\u00e9n\u00e9tration de l'aiguille ISO 11040-4 Annexe F, test de l'aiguille de seringue, et \u00e9quipement de test fiable comme le NPT-01.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.puncturetest.com\/fr\/standards\/iso-11040-4\/","og_locale":"fr_FR","og_type":"article","og_title":"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test","og_description":"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.","og_url":"https:\/\/www.puncturetest.com\/fr\/standards\/iso-11040-4\/","og_site_name":"Puncture Test","article_modified_time":"2025-07-03T07:43:22+00:00","og_image":[{"width":500,"height":400,"url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/","url":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/","name":"ISO 11040-4 M\u00e9thode d'essai de p\u00e9n\u00e9tration d'aiguille - Essai d'aiguille de seringue","isPartOf":{"@id":"https:\/\/www.puncturetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage"},"image":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage"},"thumbnailUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","datePublished":"2025-06-24T03:24:43+00:00","dateModified":"2025-07-03T07:43:22+00:00","description":"M\u00e9thode de test de p\u00e9n\u00e9tration de l'aiguille ISO 11040-4 Annexe F, test de l'aiguille de seringue, et \u00e9quipement de test fiable comme le NPT-01.","breadcrumb":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.puncturetest.com\/"},{"@type":"ListItem","position":2,"name":"Puncture Testing Standards","item":"https:\/\/www.puncturetest.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 11040-4"}]},{"@type":"WebSite","@id":"https:\/\/www.puncturetest.com\/#website","url":"https:\/\/www.puncturetest.com\/","name":"Test en capsule molle","description":"Solutions pour les tests de perforation et de p\u00e9n\u00e9trabilit\u00e9","publisher":{"@id":"https:\/\/www.puncturetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.puncturetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.puncturetest.com\/#organization","name":"Test en capsule molle","url":"https:\/\/www.puncturetest.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","width":836,"height":238,"caption":"Softgel Test"},"image":{"@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/pages\/1228","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/comments?post=1228"}],"version-history":[{"count":5,"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/pages\/1228\/revisions"}],"predecessor-version":[{"id":1299,"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/pages\/1228\/revisions\/1299"}],"up":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/pages\/974"}],"wp:attachment":[{"href":"https:\/\/www.puncturetest.com\/fr\/wp-json\/wp\/v2\/media?parent=1228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}