{"id":1135,"date":"2025-06-04T08:26:37","date_gmt":"2025-06-04T00:26:37","guid":{"rendered":"https:\/\/www.puncturetest.com\/?page_id=1135"},"modified":"2025-07-03T15:44:56","modified_gmt":"2025-07-03T07:44:56","slug":"surgical-needle-sharpness-testing","status":"publish","type":"page","link":"https:\/\/www.puncturetest.com\/lt\/surgical-needle-sharpness-testing\/","title":{"rendered":"Chirurgini\u0173 adat\u0173 a\u0161trumo bandymai \u2013 ASTM F3014"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1135\" class=\"elementor elementor-1135\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f18fd1a e-con-full e-flex e-con e-parent\" data-id=\"f18fd1a\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9d2e595 e-con-full e-flex e-con e-child\" data-id=\"9d2e595\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-562d936 e-con-full e-flex e-con e-child\" data-id=\"562d936\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d2c9de3 e-con-full e-flex e-con e-child\" data-id=\"d2c9de3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7ed2e7f elementor-widget elementor-widget-heading\" data-id=\"7ed2e7f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Chirurgini\u0173 adat\u0173 a\u0161trumo tikrinimas<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d561f2 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"3d561f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Medicinos prietais\u0173 pramon\u0117je, <em>adatos a\u0161trumo tikrinimas<\/em> yra itin svarbi proced\u016bra, u\u017etikrinanti chirurgini\u0173 adat\u0173 veikim\u0105 ir patikimum\u0105. \u012esiskverbimo j\u0117ga, reikalinga adatai prasiskverbti per pasirinkt\u0105 med\u017eiag\u0105, tiesiogiai atspindi jos a\u0161trum\u0105 ir tinkamum\u0105 naudoti klinikin\u0117je praktikoje. Nepakankamas a\u0161trumas gali sukelti audini\u0173 traumas, pabloginti chirurgini\u0173 proced\u016br\u0173 rezultatus ir netgi sukelti pacientui diskomfort\u0105. \u012emon\u0117 \u201eCell Instruments Co., Ltd.\u201c si\u016blo tikslius sprendimus adat\u0173 a\u0161trumo bandymams, leid\u017eian\u010dius atlikti tiksl\u0173 vertinim\u0105 ir pagerinti produkto kokyb\u0119.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54d30fa elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"54d30fa\" data-element_type=\"widget\" data-settings=\"{&quot;button_width&quot;:&quot;25&quot;,&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" action=\"\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"1135\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"54d30fa\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"Puncture Test\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tPavadinimas\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Pavadinimas\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-field_26b0101 elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-field_26b0101\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\t\u012emon\u0117\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[field_26b0101]\" id=\"form-field-field_26b0101\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"\u012emon\u0117\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tEl. pa\u0161tas\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"El. pa\u0161tas\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\t\u017dinut\u0117\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"\u017dinut\u0117\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-recaptcha elementor-field-group elementor-column elementor-field-group-field_50f0fd6 elementor-col-100\">\n\t\t\t\t\t<div class=\"elementor-field\" id=\"form-field-field_50f0fd6\"><div class=\"elementor-g-recaptcha\" data-sitekey=\"6LcO3HUrAAAAAKhAi3KjswdM4-_7i5zKd1s5FO2N\" data-type=\"v2_checkbox\" data-theme=\"light\" data-size=\"normal\"><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-25 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Si\u0173sti<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"lt\"\/><\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-26eab2a e-con-full e-flex e-con e-child\" data-id=\"26eab2a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-479d18a e-flex e-con-boxed e-con e-parent\" data-id=\"479d18a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c2e3a1f elementor-widget elementor-widget-heading\" data-id=\"c2e3a1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kod\u0117l reikia tikrinti adat\u0173 a\u0161trum\u0105?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48ad507 elementor-widget elementor-widget-text-editor\" data-id=\"48ad507\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Chirurgin\u0117ms adatoms taikomi grie\u017eti veikimo ir saugos reikalavimai. \u0160ios <em>ASTM F3014<\/em> Standarte ai\u0161kiai apibr\u0117\u017eti adatos \u012fsiskverbimo savybi\u0173 vertinimo metodai. Atliekant <em><a href=\"https:\/\/www.puncturetest.com\/lt\/penetrability-tester-needle-penetration-test-method\/\">adatos a\u0161trumo tikrinimas<\/a><\/em> Laikantis \u0161io standarto u\u017etikrinama, kad j\u016bs\u0173 chirurgin\u0117s adatos atitikt\u0173 eksploatacinius reikalavimus ir teis\u0117s akt\u0173 nuostatas.<\/p><p><!-- \/wp:paragraph --> <!-- wp:paragraph --><\/p><p>Pagrindin\u0117s prie\u017eastys, d\u0117l kuri\u0173 verta atlikti \u0161\u012f tyrim\u0105, yra \u0161ios:<\/p><ul><li><strong>\u012esiskverbimo j\u0117gos \u012fvertinimas:<\/strong> Siekiant u\u017etikrinti kuo ma\u017eesn\u012f pasiprie\u0161inim\u0105 ir audini\u0173 pa\u017eeidimus chirurgini\u0173 proced\u016br\u0173 metu.<\/li><li><strong>Produkt\u0173 kokyb\u0117s gerinimas:<\/strong> Adat\u0173 nuoseklumo ir patikimumo tikrinimas atliekant grie\u017etus bandymus.<\/li><li><strong>Atitiktis pramon\u0117s standartams:<\/strong> Atitinka ASTM F3014 gaires, siekiant u\u017etikrinti atitikt\u012f teis\u0117s akt\u0173 reikalavimams.<\/li><\/ul><p><!-- \/wp:list-item --><\/p><p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-12d57d9 e-flex e-con-boxed e-con e-parent\" data-id=\"12d57d9\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c75198 elementor-widget elementor-widget-heading\" data-id=\"3c75198\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ASTM F3014 standarto, skirto chirurgini\u0173 adat\u0173 bandymams, supratimas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c592e60 elementor-widget elementor-widget-text-editor\" data-id=\"c592e60\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1555\" data-end=\"1847\"><!-- wp:paragraph --><\/p><p>Svetain\u0117 <em>ASTM F3014<\/em> standartas, pavadintas <em>Standartinis chirurginiams si\u016blams naudojam\u0173 adat\u0173 \u012fsiskverbimo bandymo metodas<\/em>, pateikia i\u0161sami\u0105 tiesi\u0173 ir i\u0161lenkt\u0173 chirurgini\u0173 adat\u0173 a\u0161trumo vertinimo proced\u016br\u0105. Joje daugiausia d\u0117mesio skiriama j\u0117gos, reikalingos adatai \u012fsiskverbti kontroliuojamoje aplinkoje, matavimui.<\/p><p class=\"\" data-start=\"1555\" data-end=\"1847\"><!-- \/wp:paragraph --> <!-- wp:paragraph --><\/p><p>\u0160is standartas apima:<\/p><p class=\"\" data-start=\"1555\" data-end=\"1847\"><!-- \/wp:paragraph --> <!-- wp:list --><\/p><ul class=\"wp-block-list\"><!-- wp:list-item --><li><strong>Tyrimo metodika:<\/strong> Tiek tiesi\u0173, tiek i\u0161lenkt\u0173 adat\u0173 naudojimo proced\u016bros, u\u017etikrinan\u010dios nuoseklius ir palyginamus rezultatus.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Duomen\u0173 surinkimas:<\/strong> Rekomendacijos d\u0117l \u012fsiskverbimo j\u0117gos registravimo ne re\u010diau kaip 150 Hz da\u017eniu.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Aplinkos kontrol\u0117s priemon\u0117s:<\/strong> Bandymas atliekamas kontroliuojamoje aplinkoje (22 \u00b1 2 \u00b0C, \u226470% santykinis dr\u0117gnumas), siekiant u\u017etikrinti bandymo tikslum\u0105.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>M\u0117gini\u0173 \u0117mimo reikalavimai:<\/strong> Siekiant gauti patikimus duomenis, buvo i\u0161bandyta ne ma\u017eiau kaip 30 adat\u0173, kiekviena i\u0161 j\u0173 buvo pakartotinai \u012fsmeigiama ne ma\u017eiau kaip de\u0161imt kart\u0173.<\/li><!-- \/wp:list-item --><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3b029b0 e-flex e-con-boxed e-con e-parent\" data-id=\"3b029b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09228fb elementor-widget elementor-widget-heading\" data-id=\"09228fb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Adatos a\u0161trumo tikrinimas: pagrindiniai \u017eingsniai<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56d2ff5 elementor-widget elementor-widget-text-editor\" data-id=\"56d2ff5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><!-- wp:paragraph --><\/p><p>Nor\u0117dami u\u017etikrinti patikimus ir tikslius rezultatus, atlikite \u0161iuos svarbius veiksmus, atitinkan\u010dius <em>ASTM F3014<\/em>:<\/p><p><!-- \/wp:paragraph --> <!-- wp:list --><\/p><ul class=\"wp-block-list\"><!-- wp:list-item --><li><strong>Adatos paruo\u0161imas:<\/strong> Patikrinkite kiekvien\u0105 adat\u0105, kad \u012fsitikintum\u0117te, jog ji atitinka kokyb\u0117s standartus ir neturi joki\u0173 matom\u0173 deformacij\u0173.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Adatos fiksavimas:<\/strong> Adat\u0105 reikia tolygiai prispausti prie\u0161ais tvirtinimo zon\u0105 arba liestin\u0119 dal\u012f, esan\u010di\u0105 toliau nuo adatos galiuko. Adata turi b\u016bti statmena tiriamajai med\u017eiagai.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Rungtyni\u0173 tvarkara\u0161\u010dio sudarymas:<\/strong> Bandymo \u012ftaisas sukasi taip, kad adata b\u016bt\u0173 \u012fstumta \u012f terp\u0119 40\u00b0 kampu, kaip nurodyta standarte.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>\u012esilau\u017eimo testavimas:<\/strong> Bandym\u0105 atlikite vienodu grei\u010diu, u\u017etikrindami, kad kiekvienas \u012fsiskverbimas vykt\u0173 naujoje, dar neperdurtoje terp\u0117s vietoje, siekiant i\u0161laikyti duomen\u0173 vientisum\u0105.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Priverstinis duomen\u0173 rinkimas:<\/strong> Nuolat registruokite kiekvienam \u012fsiskverbimui reikaling\u0105 j\u0117g\u0105, kad gautum\u0117te tikslius matavimus.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Pakartokite ir u\u017efiksuokite:<\/strong> Atlikite ne ma\u017eiau kaip de\u0161imt \u012fsiskverbimo bandym\u0173 kiekvienai adatai, kiekvien\u0105 kart\u0105 pereidami \u012f nauj\u0105 srit\u012f, kad i\u0161vengtum\u0117te duomen\u0173 i\u0161kraipymo.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Duomen\u0173 analiz\u0117:<\/strong> Apskai\u010diuokite ir nurodykite vidutin\u0119 \u012fsiskverbimo j\u0117g\u0105 niutonais, u\u017etikrindami, kad rezultatai atspind\u0117t\u0173 tikr\u0105sias adatos charakteristikas.<\/li><!-- \/wp:list-item --><\/ul><p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b190634 e-flex e-con-boxed e-con e-parent\" data-id=\"b190634\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-effa359 elementor-widget elementor-widget-heading\" data-id=\"effa359\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Geriausios praktikos, u\u017etikrinan\u010dios tikslius chirurgini\u0173 adat\u0173 bandymus<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98aaa3c elementor-widget elementor-widget-text-editor\" data-id=\"98aaa3c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Norint gauti tikslius ir pakartojamus rezultatus:<\/p>\n<ul>\n<li><strong>Naudokite tinkamus tvirtinimo \u012ftaisus:<\/strong> Pritvirtinkite adat\u0105 taip, kad ji nesulankstyt\u0173 ir nei\u0161sikreipt\u0173, kad duomenys b\u016bt\u0173 tiksl\u016bs.<\/li>\n<li><strong>Pasirinkite tinkam\u0105 bandymo terp\u0119:<\/strong> Nors <a href=\"https:\/\/www.astm.org\/f3014-14.html\" target=\"_blank\" rel=\"noopener\">ASTM F3014<\/a> jei terp\u0117 nenurodyta, pasirinkite toki\u0105, kuri imituoja audini\u0173 savybes, kad vertinimas b\u016bt\u0173 kuo realisti\u0161kesnis.<\/li>\n<li><strong>Suma\u017einti svyravimus:<\/strong> U\u017etikrinkite aplinkos veiksni\u0173 pastovum\u0105 ir naudokite patikimas duomen\u0173 surinkimo sistemas.<\/li>\n<li><strong>U\u017etikrinkite, kad bandymo pavir\u0161iai b\u016bt\u0173 \u0161var\u016bs:<\/strong> Kiekvieno bandymo ciklo metu pereikite \u012f dar neapdorot\u0105 plot\u0105, kad i\u0161vengtum\u0117te ankstesni\u0173 skyli\u0173 sukeliam\u0173 trukd\u017ei\u0173.<\/li>\n<\/ul>\n<p><!-- \/wp:list-item --><\/p>\n<p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-edca2e3 e-flex e-con-boxed e-con e-parent\" data-id=\"edca2e3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f445dd8 elementor-widget elementor-widget-heading\" data-id=\"f445dd8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bendradarbiavimo su \u201eCell Instruments Co., Ltd.\u201c privalumai.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88da2c6 elementor-widget elementor-widget-text-editor\" data-id=\"88da2c6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><!-- wp:paragraph --><\/p><p>\u201eCell Instruments Co., Ltd.\u201c specializuojasi teikiant pa\u017eangias <em>adatos a\u0161trumo tikrinimas<\/em> sprendimai, pritaikyti j\u016bs\u0173 poreikiams. M\u016bs\u0173 tikslieji prietaisai u\u017etikrina atitikt\u012f <em>ASTM F3014<\/em> ir pateikti tikslius, patikimus duomenis, reikalingus produkto patvirtinimui.<\/p><p><!-- \/wp:paragraph --> <!-- wp:paragraph --><\/p><p>Taip pat si\u016blome:<\/p><p><!-- \/wp:paragraph --> <!-- wp:list --><\/p><ul class=\"wp-block-list\"><!-- wp:list-item --><li><strong>Individualizuoti testavimo sprendimai:<\/strong> Sukurta siekiant patenkinti j\u016bs\u0173 unikalius bandym\u0173 reikalavimus, \u012fskaitant automatizavim\u0105 ir integracij\u0105 su kokyb\u0117s sistemomis.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Ekspert\u0173 pagalba:<\/strong> M\u016bs\u0173 kompetentinga komanda teikia technin\u0119 pagalb\u0105 ir rengia mokymus, kurie pad\u0117s jums optimizuoti testavimo procesus.<\/li><!-- \/wp:list-item --> <!-- wp:list-item --><li><strong>Platus pritaikymas:<\/strong> Nuo pakavimo iki medicinos prietais\u0173 bandym\u0173 \u2013 m\u016bs\u0173 prietaisai tinka \u012fvairioms med\u017eiagoms ir pramon\u0117s \u0161akoms.<\/li><!-- \/wp:list-item --><\/ul><p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4be815d e-con-full e-flex e-con e-parent\" data-id=\"4be815d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a575706 elementor-cta--skin-classic elementor-animated-content elementor-bg-transform elementor-bg-transform-zoom-in elementor-widget elementor-widget-call-to-action\" data-id=\"a575706\" data-element_type=\"widget\" data-widget_type=\"call-to-action.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-cta\">\n\t\t\t\t\t<div class=\"elementor-cta__bg-wrapper\">\n\t\t\t\t<div class=\"elementor-cta__bg elementor-bg\" style=\"background-image: url(https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/02\/Elastomeric-Closures-Penetrability-Test-1024x256.webp);\" role=\"img\" aria-label=\"Elastomerini\u0173 dangteli\u0173 pralaidumo bandymas\"><\/div>\n\t\t\t\t<div class=\"elementor-cta__bg-overlay\"><\/div>\n\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-cta__content\">\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h2 class=\"elementor-cta__title elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tChirurgini\u0173 adat\u0173 a\u0161trumo tikrinimo sprendimas \u2013 susisiekite su mumis, jei norite su\u017einoti daugiau\t\t\t\t\t<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__description elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\t<b><i>Adatos a\u0161trumo tikrinimas<\/i><\/b> remiantis <b><i>ASTM F3014<\/i><\/b> yra b\u016btinas chirurgini\u0173 adat\u0173 veikimo ir kokyb\u0117s patikrinimui. Laikydamiesi nurodyt\u0173 proced\u016br\u0173, galite u\u017etikrinti, kad j\u016bs\u0173 adatos atitikt\u0173 auk\u0161tus pacient\u0173 saugos ir chirurginio veiksmingumo standartus. Pasitik\u0117kite \u201eCell Instruments Co., Ltd.\u201c \u2013 mes suteiksime jums tikslius prietaisus ir param\u0105, reikaling\u0105 tiksliam bandymui ir nuolatiniam tobulinimui.\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__button-wrapper elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t<a class=\"elementor-cta__button elementor-button elementor-size-\" href=\"https:\/\/www.puncturetest.com\/lt\/contact\/\">\n\t\t\t\t\t\tSusisiekite su mumis\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Chirurgini\u0173 adat\u0173 a\u0161trumo testavimas Medicinos prietais\u0173 pramon\u0117je adat\u0173 a\u0161trumo testavimas yra labai svarbi proced\u016bra, u\u017etikrinanti chirurgini\u0173 adat\u0173 veikim\u0105 ir patikimum\u0105. \u012esiskverbimo j\u0117ga, reikalinga adatai prasiskverbti pro pasirinkt\u0105 terp\u0119, tiesiogiai atspindi jos a\u0161trum\u0105 ir tinkamum\u0105 naudoti klinikin\u0117je praktikoje. Prastas a\u0161trumas gali sukelti audini\u0173 traum\u0105, pakenkti [...]<\/p>","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-1135","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Surgical Needle Sharpness Testing - ASTM F3014<\/title>\n<meta name=\"description\" content=\"Needle sharpness testing based on ASTM F3014. Learn how to perform surgical needle testing for quality control and product integrity.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.puncturetest.com\/lt\/surgical-needle-sharpness-testing\/\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Surgical Needle Sharpness Testing - ASTM F3014\" \/>\n<meta property=\"og:description\" content=\"Needle sharpness testing based on ASTM F3014. Learn how to perform surgical needle testing for quality control and product integrity.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.puncturetest.com\/lt\/surgical-needle-sharpness-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"Puncture Test\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-03T07:44:56+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/\",\"url\":\"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/\",\"name\":\"Surgical Needle Sharpness Testing - ASTM F3014\",\"isPartOf\":{\"@id\":\"https:\/\/www.puncturetest.com\/#website\"},\"datePublished\":\"2025-06-04T00:26:37+00:00\",\"dateModified\":\"2025-07-03T07:44:56+00:00\",\"description\":\"Needle sharpness testing based on ASTM F3014. Learn how to perform surgical needle testing for quality control and product integrity.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.puncturetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Surgical Needle Sharpness Testing &#8211; ASTM F3014\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.puncturetest.com\/#website\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"name\":\"Softgel Test\",\"description\":\"Puncture and Penetrabiity Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.puncturetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.puncturetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.puncturetest.com\/#organization\",\"name\":\"Softgel Test\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"width\":836,\"height\":238,\"caption\":\"Softgel Test\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Chirurgini\u0173 adat\u0173 a\u0161trumo bandymai \u2013 ASTM F3014","description":"Adat\u0173 a\u0161trumo tikrinimas pagal ASTM F3014 standart\u0105. Su\u017einokite, kaip atlikti chirurgini\u0173 adat\u0173 bandymus kokyb\u0117s kontrolei ir produkto vientisumui u\u017etikrinti.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.puncturetest.com\/lt\/surgical-needle-sharpness-testing\/","og_locale":"lt_LT","og_type":"article","og_title":"Surgical Needle Sharpness Testing - ASTM F3014","og_description":"Needle sharpness testing based on ASTM F3014. Learn how to perform surgical needle testing for quality control and product integrity.","og_url":"https:\/\/www.puncturetest.com\/lt\/surgical-needle-sharpness-testing\/","og_site_name":"Puncture Test","article_modified_time":"2025-07-03T07:44:56+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/","url":"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/","name":"Chirurgini\u0173 adat\u0173 a\u0161trumo bandymai \u2013 ASTM F3014","isPartOf":{"@id":"https:\/\/www.puncturetest.com\/#website"},"datePublished":"2025-06-04T00:26:37+00:00","dateModified":"2025-07-03T07:44:56+00:00","description":"Adat\u0173 a\u0161trumo tikrinimas pagal ASTM F3014 standart\u0105. Su\u017einokite, kaip atlikti chirurgini\u0173 adat\u0173 bandymus kokyb\u0117s kontrolei ir produkto vientisumui u\u017etikrinti.","breadcrumb":{"@id":"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.puncturetest.com\/surgical-needle-sharpness-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.puncturetest.com\/"},{"@type":"ListItem","position":2,"name":"Surgical Needle Sharpness Testing &#8211; ASTM F3014"}]},{"@type":"WebSite","@id":"https:\/\/www.puncturetest.com\/#website","url":"https:\/\/www.puncturetest.com\/","name":"Mink\u0161t\u0173j\u0173 geli\u0173 testas","description":"Perforacijos ir penetracijos test\u0173 sprendimai","publisher":{"@id":"https:\/\/www.puncturetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.puncturetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/www.puncturetest.com\/#organization","name":"Mink\u0161t\u0173j\u0173 geli\u0173 testas","url":"https:\/\/www.puncturetest.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","width":836,"height":238,"caption":"Softgel Test"},"image":{"@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages\/1135","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/comments?post=1135"}],"version-history":[{"count":5,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages\/1135\/revisions"}],"predecessor-version":[{"id":1314,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages\/1135\/revisions\/1314"}],"wp:attachment":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/media?parent=1135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}