{"id":1228,"date":"2025-06-24T11:24:43","date_gmt":"2025-06-24T03:24:43","guid":{"rendered":"https:\/\/www.puncturetest.com\/?page_id=1228"},"modified":"2025-07-03T15:43:22","modified_gmt":"2025-07-03T07:43:22","slug":"iso-11040-4","status":"publish","type":"page","link":"https:\/\/www.puncturetest.com\/lt\/standards\/iso-11040-4\/","title":{"rendered":"ISO 11040-4"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1228\" class=\"elementor elementor-1228\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c60fdbb e-flex e-con-boxed e-con e-parent\" data-id=\"c60fdbb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-db6fcba e-con-full e-flex e-con e-child\" data-id=\"db6fcba\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9d1f798 e-con-full e-flex e-con e-child\" data-id=\"9d1f798\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-8cc5a79 e-con-full e-flex e-con e-child\" data-id=\"8cc5a79\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6b67d4 elementor-widget elementor-widget-heading\" data-id=\"b6b67d4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4<br><small>Needle Penetration Test<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69f526a elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"69f526a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"201\">Ensuring the performance and safety of prefilled syringes is vital in medical and pharmaceutical applications. <strong data-start=\"521\" data-end=\"536\">ISO 11040-4<\/strong> outlines the essential specifications for <strong data-start=\"579\" data-end=\"667\">glass barrels for injectables and sterilized subassembled syringes ready for filling<\/strong>. One of the critical quality assessments under this standard is the <strong data-start=\"736\" data-end=\"770\">needle penetration test method<\/strong>, which evaluates how easily a syringe needle penetrates a standard material.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eff30d4 elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"eff30d4\" data-element_type=\"widget\" data-settings=\"{&quot;button_width&quot;:&quot;25&quot;,&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" action=\"\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"1228\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"eff30d4\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"Puncture Test\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tPavadinimas\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Pavadinimas\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-field_26b0101 elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-field_26b0101\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\t\u012emon\u0117\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[field_26b0101]\" id=\"form-field-field_26b0101\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"\u012emon\u0117\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tEl. pa\u0161tas\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"El. pa\u0161tas\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\t\u017dinut\u0117\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"\u017dinut\u0117\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-recaptcha elementor-field-group elementor-column elementor-field-group-field_50f0fd6 elementor-col-100\">\n\t\t\t\t\t<div class=\"elementor-field\" id=\"form-field-field_50f0fd6\"><div class=\"elementor-g-recaptcha\" data-sitekey=\"6LcO3HUrAAAAAKhAi3KjswdM4-_7i5zKd1s5FO2N\" data-type=\"v2_checkbox\" data-theme=\"light\" data-size=\"normal\"><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-25 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Si\u0173sti<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"lt\"\/><\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-163fe1b e-con-full e-flex e-con e-child\" data-id=\"163fe1b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f2b60d e-flex e-con-boxed e-con e-parent\" data-id=\"3f2b60d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c5f6d2 elementor-widget elementor-widget-heading\" data-id=\"7c5f6d2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What Is ISO 11040-4 and Why It Matters<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6126588 elementor-widget elementor-widget-text-editor\" data-id=\"6126588\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1111\" data-end=\"1465\"><strong data-start=\"1111\" data-end=\"1126\">ISO 11040-4<\/strong> is a globally recognized standard in the ISO 11040 series that specifically addresses <strong data-start=\"1213\" data-end=\"1246\">glass barrels for injectables<\/strong> ir <strong data-start=\"1251\" data-end=\"1288\">pre-assembled sterilized syringes<\/strong> intended for aseptic filling. It ensures that these components meet strict dimensional and functional criteria to maintain product sterility, compatibility, and patient safety.<\/p><p data-start=\"1467\" data-end=\"1763\">A significant part of this standard is the <strong data-start=\"1510\" data-end=\"1537\">needle penetration test<\/strong>, which verifies the <strong data-start=\"1558\" data-end=\"1584\">mechanical performance<\/strong> of the needle during usage. The ease with which a needle can pierce a substrate reflects on its <strong data-start=\"1681\" data-end=\"1731\">sharpness, material quality, surface treatment<\/strong>, and manufacturing consistency.<\/p><p data-start=\"1765\" data-end=\"1794\">This testing is critical for:<\/p><ul><li data-start=\"1798\" data-end=\"1858\">Ensuring smooth injections with minimal patient discomfort<\/li><li data-start=\"1861\" data-end=\"1900\">Preventing needle breakage or bending<\/li><li data-start=\"1903\" data-end=\"1956\">Guaranteeing compatibility with packaging materials<\/li><li data-start=\"1959\" data-end=\"2008\">Confirming compliance for regulatory submission<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-580df19 e-flex e-con-boxed e-con e-parent\" data-id=\"580df19\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8262e73 elementor-widget elementor-widget-heading\" data-id=\"8262e73\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Needle Penetration Test Method Explained<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c71437 elementor-widget elementor-widget-text-editor\" data-id=\"7c71437\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2061\" data-end=\"2365\">Svetain\u0117 <strong data-start=\"2065\" data-end=\"2099\">needle penetration test method<\/strong>, as detailed in Annex F of ISO 11040-4, assesses the <strong data-start=\"2153\" data-end=\"2222\">force required for a syringe needle to pierce a defined test foil<\/strong>. This procedure is derived from DIN 13097-4 and is referenced in <a href=\"https:\/\/www.puncturetest.com\/lt\/standards\/iso-7864-needle-penetration-drag-force-test\/\"><strong data-start=\"2288\" data-end=\"2300\">ISO 7864<\/strong><\/a>kitas svarbus standartas, taikomas sterilioms poodin\u0117ms adatoms.<\/p><p data-start=\"2367\" data-end=\"2404\">Key components of the method include:<\/p><ul><li data-start=\"2408\" data-end=\"2534\"><strong data-start=\"2408\" data-end=\"2426\">Test apparatus<\/strong>: A <strong data-start=\"2430\" data-end=\"2474\">universal tensile and compression tester<\/strong> with a force range up to 10 N and a speed of 20\u2013200 mm\/min.<\/li><li data-start=\"2537\" data-end=\"2612\"><strong data-start=\"2537\" data-end=\"2554\">Sampling rate<\/strong>: 500 Hz is recommended for accurate peak force detection.<\/li><li data-start=\"2615\" data-end=\"2685\"><strong data-start=\"2615\" data-end=\"2632\">Needle holder<\/strong>: Ensures vertical alignment for precise penetration.<\/li><li data-start=\"2688\" data-end=\"2779\"><strong data-start=\"2688\" data-end=\"2701\">Test foil<\/strong>: Material and thickness are to be agreed upon by the manufacturer and client.<\/li><li data-start=\"2782\" data-end=\"2861\"><strong data-start=\"2782\" data-end=\"2800\">Needle samples<\/strong>: Can be siliconized or untreated, depending on intended use.<\/li><li data-start=\"2864\" data-end=\"2992\"><strong data-start=\"2864\" data-end=\"2883\">Data collection<\/strong>: A <strong data-start=\"2887\" data-end=\"2919\">force vs. displacement curve<\/strong> is generated for each test, measuring <strong data-start=\"2958\" data-end=\"2972\">peak force<\/strong> ir <strong data-start=\"2977\" data-end=\"2991\">pasiprie\u0161inimo j\u0117ga<\/strong>.<\/li><\/ul><p data-start=\"2994\" data-end=\"3141\">The method guarantees that the <strong data-start=\"3025\" data-end=\"3068\">needle sharpness and coating uniformity<\/strong> are within acceptable parameters, ensuring reliable syringe performance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a9693b2 e-flex e-con-boxed e-con e-parent\" data-id=\"a9693b2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b44c843 elementor-widget elementor-widget-heading\" data-id=\"b44c843\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Syringe Needle Test Best Practices<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e38b53 elementor-widget elementor-widget-text-editor\" data-id=\"3e38b53\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3188\" data-end=\"3329\">When conducting a <strong data-start=\"3206\" data-end=\"3229\">syringe needle test<\/strong>, it&#8217;s essential to follow ISO guidelines while optimizing the process for consistency and accuracy:<\/p><ol><li><strong data-start=\"3334\" data-end=\"3362\">Use validated substrates<\/strong>: Such as <strong data-start=\"3372\" data-end=\"3388\">latex rubber<\/strong>, <strong data-start=\"3390\" data-end=\"3406\">polyurethane<\/strong>, or <strong data-start=\"3411\" data-end=\"3427\">polyethylene<\/strong> that mimic skin or packaging conditions.<\/li><li><strong data-start=\"3472\" data-end=\"3507\">Control environmental variables<\/strong>: Maintain consistent <strong data-start=\"3529\" data-end=\"3557\">temperature and humidity<\/strong> during testing.<\/li><li><strong data-start=\"3577\" data-end=\"3599\">Avoid sample reuse<\/strong>: Each test must use a fresh section of foil or substrate.<\/li><li><strong data-start=\"3661\" data-end=\"3683\">Ensure calibration<\/strong>: The testing machine should be calibrated regularly with traceable standards.<\/li><li><strong data-start=\"3765\" data-end=\"3788\">Document thoroughly<\/strong>: Include foil specifications, test speed, number of samples, and all force curves in the test report.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a6df764 e-flex e-con-boxed e-con e-parent\" data-id=\"a6df764\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15bd215 elementor-widget elementor-widget-heading\" data-id=\"15bd215\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.puncturetest.com\/lt\/tissue-paper-ball-burst-strength-test\/\">Needle Penetration Test Equipment for ISO 11040-4 Compliance<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e5f91e3 e-con-full e-flex e-con e-child\" data-id=\"e5f91e3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-44c6d75 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"44c6d75\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3963\" data-end=\"4156\">For labs and manufacturers needing to perform needle penetration tests in line with ISO 11040-4, <strong data-start=\"4060\" data-end=\"4114\">Cell Instruments\u2019 NPT-01 Needle Penetration Tester<\/strong> is a reliable, high-performance solution.<\/p><p data-start=\"4158\" data-end=\"4197\">Key features of the <strong data-start=\"4178\" data-end=\"4188\">NPT-01<\/strong> include:<\/p><ul><li>High-precision force sensors with \u00b10.5% accuracy<\/li><li>Adjustable test speeds from 20 mm\/min to 200 mm\/min<\/li><li>Real-time <strong data-start=\"4320\" data-end=\"4349\">force-displacement curves<\/strong> with exportable data<\/li><li>Customizable needle holders and foil clamps<\/li><li>Compatible with various syringe sizes and needle gauges<\/li><\/ul><p data-start=\"4482\" data-end=\"4726\">Using the <strong data-start=\"4492\" data-end=\"4502\">NPT-01<\/strong> streamlines compliance with ISO 11040-4 and ISO 7864 while reducing variability and enhancing data integrity. It is particularly well-suited for <strong data-start=\"4648\" data-end=\"4684\">R&amp;D laboratories, QC departments<\/strong>, ir <strong data-start=\"4690\" data-end=\"4725\">regulatory validation processes<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5f0632 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"e5f0632\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.puncturetest.com\/lt\/penetrability-tester-needle-penetration-test-method\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"400\" src=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\" class=\"attachment-full size-full wp-image-1230\" alt=\"ISO 11040-4 Needle Penetration Test Method\" srcset=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp 500w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method-300x240.webp 300w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method-15x12.webp 15w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6821011 e-con-full e-flex e-con e-parent\" data-id=\"6821011\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-665057d elementor-cta--skin-classic elementor-animated-content elementor-bg-transform elementor-bg-transform-zoom-in elementor-widget elementor-widget-call-to-action\" data-id=\"665057d\" data-element_type=\"widget\" data-widget_type=\"call-to-action.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-cta\">\n\t\t\t\t\t<div class=\"elementor-cta__bg-wrapper\">\n\t\t\t\t<div class=\"elementor-cta__bg elementor-bg\" style=\"background-image: url(https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/02\/Elastomeric-Closures-Penetrability-Test-1024x256.webp);\" role=\"img\" aria-label=\"Elastomerini\u0173 dangteli\u0173 pralaidumo bandymas\"><\/div>\n\t\t\t\t<div class=\"elementor-cta__bg-overlay\"><\/div>\n\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-cta__content\">\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h2 class=\"elementor-cta__title elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tEnsure Your Syringe Needle Compliance Today\t\t\t\t\t<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__description elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tUnderstanding and applying the <b>ISO 11040-4 needle penetration test method<\/b> is vital for any manufacturer producing <b>prefilled syringes or hypodermic needles<\/b>. The standard provides clear guidelines for equipment, test procedure, and reporting to ensure needle integrity and patient safety. By integrating <b>reliable syringe needle test equipment<\/b> kaip ir <b>Puncturetest.com NPT-01<\/b>, companies can streamline compliance, reduce risk, and elevate product quality.\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__button-wrapper elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t<a class=\"elementor-cta__button elementor-button elementor-size-\" href=\"https:\/\/www.puncturetest.com\/lt\/contact\/\">\n\t\t\t\t\t\tSpauskite \u010dia\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 11040-4Needle Penetration Test Ensuring the performance and safety of prefilled syringes is vital in medical and pharmaceutical applications. ISO 11040-4 outlines the essential specifications for glass barrels for injectables and sterilized subassembled syringes ready for filling. One of the critical quality assessments under this standard is the needle penetration test method, which evaluates how [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"parent":974,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1228","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test<\/title>\n<meta name=\"description\" content=\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.puncturetest.com\/lt\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:locale\" content=\"lt_LT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test\" \/>\n<meta property=\"og:description\" content=\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.puncturetest.com\/lt\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:site_name\" content=\"Puncture Test\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-03T07:43:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minut\u0117s\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\",\"url\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\",\"name\":\"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test\",\"isPartOf\":{\"@id\":\"https:\/\/www.puncturetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\",\"datePublished\":\"2025-06-24T03:24:43+00:00\",\"dateModified\":\"2025-07-03T07:43:22+00:00\",\"description\":\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb\"},\"inLanguage\":\"lt-LT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.puncturetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Puncture Testing Standards\",\"item\":\"https:\/\/www.puncturetest.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 11040-4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.puncturetest.com\/#website\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"name\":\"Softgel Test\",\"description\":\"Puncture and Penetrabiity Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.puncturetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.puncturetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lt-LT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.puncturetest.com\/#organization\",\"name\":\"Softgel Test\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lt-LT\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"width\":836,\"height\":238,\"caption\":\"Softgel Test\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test","description":"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.puncturetest.com\/lt\/standards\/iso-11040-4\/","og_locale":"lt_LT","og_type":"article","og_title":"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test","og_description":"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.","og_url":"https:\/\/www.puncturetest.com\/lt\/standards\/iso-11040-4\/","og_site_name":"Puncture Test","article_modified_time":"2025-07-03T07:43:22+00:00","og_image":[{"width":500,"height":400,"url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minut\u0117s"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/","url":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/","name":"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test","isPartOf":{"@id":"https:\/\/www.puncturetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage"},"image":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage"},"thumbnailUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","datePublished":"2025-06-24T03:24:43+00:00","dateModified":"2025-07-03T07:43:22+00:00","description":"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.","breadcrumb":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb"},"inLanguage":"lt-LT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/"]}]},{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.puncturetest.com\/"},{"@type":"ListItem","position":2,"name":"Puncture Testing Standards","item":"https:\/\/www.puncturetest.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 11040-4"}]},{"@type":"WebSite","@id":"https:\/\/www.puncturetest.com\/#website","url":"https:\/\/www.puncturetest.com\/","name":"Mink\u0161t\u0173j\u0173 geli\u0173 testas","description":"Perforacijos ir penetracijos test\u0173 sprendimai","publisher":{"@id":"https:\/\/www.puncturetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.puncturetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lt-LT"},{"@type":"Organization","@id":"https:\/\/www.puncturetest.com\/#organization","name":"Mink\u0161t\u0173j\u0173 geli\u0173 testas","url":"https:\/\/www.puncturetest.com\/","logo":{"@type":"ImageObject","inLanguage":"lt-LT","@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","width":836,"height":238,"caption":"Softgel Test"},"image":{"@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages\/1228","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/comments?post=1228"}],"version-history":[{"count":5,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages\/1228\/revisions"}],"predecessor-version":[{"id":1299,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages\/1228\/revisions\/1299"}],"up":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/pages\/974"}],"wp:attachment":[{"href":"https:\/\/www.puncturetest.com\/lt\/wp-json\/wp\/v2\/media?parent=1228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}