{"id":1478,"date":"2026-03-23T15:47:16","date_gmt":"2026-03-23T07:47:16","guid":{"rendered":"https:\/\/www.puncturetest.com\/?p=1478"},"modified":"2026-03-23T15:47:17","modified_gmt":"2026-03-23T07:47:17","slug":"drag-force-test","status":"publish","type":"post","link":"https:\/\/www.puncturetest.com\/lv\/drag-force-test\/","title":{"rendered":"Test for Penetrability: Understanding Needle Penetration Force and Drag Force Test Based on ISO 7864"},"content":{"rendered":"<p>Port\u0101ls <strong>test for penetrability<\/strong> is a critical method used to evaluate the performance of needles in terms of their ability to penetrate various substrates. In industries like medical device manufacturing, packaging, and materials testing, understanding the force required for needle penetration can significantly impact product design and quality control. This article explores the <strong>adatas iespie\u0161an\u0101s sp\u0113ka tests<\/strong>, un <strong>drag force test<\/strong>, and the standards set by <strong>ISO 7864<\/strong> to help professionals assess and ensure the reliability of needle-based products.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Understanding the Test for Penetrability<\/h2>\n\n\n\n<p>A <strong>test for penetrability<\/strong> evaluates how much force is required for a needle to penetrate a material. This type of test is especially important for ensuring that needles, such as hypodermic needles, are designed to easily enter tissues or other materials without causing excessive force or damage. The force profile during penetration helps assess both the initial resistance (penetration force) and the frictional resistance (drag force) encountered by the needle as it moves through the material.<\/p>\n\n\n\n<p>For accurate and consistent results, this test must be performed under controlled conditions, using standard substrates and precise equipment to measure forces at different stages of penetration.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/www.puncturetest.com\/lv\/penetrability-tester-needle-penetration-test-method\/\" target=\"_blank\" rel=\" noreferrer noopener\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp\" alt=\"Test for Penetrability Needle Penetration Force and Drag Force Test with ISO 7864\" class=\"wp-image-1480\" style=\"width:782px;height:auto\" srcset=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp 600w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864-300x300.webp 300w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864-150x150.webp 150w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">The Needle Penetration Force Test<\/h2>\n\n\n\n<p>Port\u0101ls <strong>adatas iespie\u0161an\u0101s sp\u0113ka tests<\/strong> is used to measure the force required to insert a needle into a defined substrate. This test is particularly relevant for industries involved in needle-based products, such as syringes, medical devices, and injection systems.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Initial Penetration Force<\/strong>: The force required to initiate penetration of the needle into the substrate.<\/li>\n\n\n\n<li><strong>Drag Force<\/strong>: The frictional force experienced by the needle as it moves through the substrate.<\/li>\n<\/ul>\n\n\n\n<p>The test is typically carried out at a standard speed of 100 mm\/min, as recommended in <strong>ISO 7864<\/strong>. Port\u0101ls <strong>NPD-01 Needle Penetration and Drag Force Tester<\/strong> is an ideal tool for performing this test, providing accurate force measurements during both insertion and retraction phases.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Role of ISO 7864 in Needle Penetration Testing<\/h2>\n\n\n\n<p><strong>ISO 7864<\/strong> provides the standard requirements and test methods for sterile hypodermic needles for single-use applications. The standard specifies the procedures for measuring penetration force and drag force, offering a framework for assessing the performance of needles in terms of both their strength and smoothness during penetration.<\/p>\n\n\n\n<p>According to <strong>ISO 7864<\/strong>, the test apparatus includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Sp\u0113ka m\u0113r\u012b\u0161anas apar\u0101ts<\/strong>: A load cell to measure the force during different stages of needle penetration.<\/li>\n\n\n\n<li><strong>Substrate Holder<\/strong>: A device to hold the test substrate, ensuring consistency and stability during testing.<\/li>\n\n\n\n<li><strong>Needle Insertion Speed<\/strong>: Typically set at 100 mm\/min for standard penetration tests.<\/li>\n<\/ul>\n\n\n\n<p>The standard also outlines the types of substrates suitable for testing, such as latex rubber, polyurethane, and silicone, each offering different levels of resistance and frictional forces.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Needle Penetration Test Method<\/h2>\n\n\n\n<p>Port\u0101ls <strong>needle penetration test method<\/strong> involves inserting the needle into a substrate at a constant speed while measuring the force exerted at various points along the way. This process typically includes the following steps:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Sample Preparation<\/strong>: Both the needle and the substrate are prepared under standard ambient conditions, ensuring that they are free from defects or contaminants that could affect the results.<\/li>\n\n\n\n<li><strong>Needle Insertion<\/strong>: The needle is mounted in a force measurement apparatus and inserted into the substrate at a predefined speed.<\/li>\n\n\n\n<li><strong>Force Measurement<\/strong>: The test measures the <strong>maksim\u0101lais iespie\u0161an\u0101s sp\u0113ks<\/strong> (the maximum force required for initial penetration) and the <strong>pretest\u012bbas sp\u0113ks<\/strong> (the force required to maintain movement through the substrate).<\/li>\n\n\n\n<li><strong>Data Analysis<\/strong>: The force profile is recorded and analyzed to calculate the average drag force and maximum penetration force.<\/li>\n<\/ol>\n\n\n\n<p>These values are essential for assessing the quality of needle-based products, ensuring they function properly in real-world applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Drag Force Test<\/h2>\n\n\n\n<p>Port\u0101ls <strong>drag force test<\/strong> is specifically focused on measuring the frictional resistance encountered by the needle as it moves through the substrate. This force is important for understanding how easily the needle moves after the initial penetration.<\/p>\n\n\n\n<p>Drag force is particularly relevant when considering the comfort and ease of use of needles in medical applications. High drag forces can make needles harder to insert, potentially leading to patient discomfort or a higher risk of complications. Understanding and optimizing drag force helps manufacturers create more efficient and comfortable needle designs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Equipment for Needle Penetration and Drag Force Testing<\/h2>\n\n\n\n<p>Port\u0101ls <strong>NPD-01 Needle Penetration and Drag Force Tester<\/strong> no <strong>\u0160\u016bnu instrumenti<\/strong> is specifically designed to perform <strong>needle penetration tests<\/strong> un <strong>drag force tests<\/strong>. This precision instrument is equipped with advanced features such as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Load Cell Measurement<\/strong>: Provides accurate force readings for both initial penetration and drag force.<\/li>\n\n\n\n<li><strong>Adjustable Test Speed<\/strong>: Supports various testing speeds to meet different testing standards, including ISO 7864.<\/li>\n\n\n\n<li><strong>Multiple Substrate Compatibility<\/strong>: Can be used with a variety of substrates, such as latex rubber, polyurethane, and silicone, ensuring versatility in testing.<\/li>\n<\/ul>\n\n\n\n<p>By using the <strong>NPD-01 Needle Penetration and Drag Force Tester<\/strong>, manufacturers can ensure their products meet international standards and provide reliable, comfortable, and effective performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Secin\u0101jums<\/h2>\n\n\n\n<p>Port\u0101ls <strong>test for penetrability<\/strong> is an essential procedure for evaluating the performance of needles in various applications, from medical devices to packaging. By measuring both <strong>adatas iespie\u0161an\u0101s sp\u0113ks<\/strong> un <strong>pretest\u012bbas sp\u0113ks<\/strong>, this test provides valuable data on the mechanical properties of needles and their interaction with different substrates.<\/p>\n\n\n\n<p><strong>ISO 7864<\/strong> sets the standard for performing these tests, ensuring consistency and reliability across the industry. The <strong>NPD-01 Needle Penetration and Drag Force Tester<\/strong> offers a robust solution for performing these tests with high precision, helping manufacturers meet quality control standards and produce superior needle-based products.<\/p>\n\n\n\n<p>For more accurate and reliable <strong>needle penetration testing<\/strong>, <strong>\u0160\u016bnu instrumenti<\/strong> provides state-of-the-art testing equipment tailored to meet industry requirements. Ensure the quality and performance of your needle products with our advanced <strong>Needle Penetration and Drag Force Testers<\/strong>.<\/p>\n\n\n\n<p><br>Ensure the quality of your needle-based products with the <strong>NPD-01 Needle Penetration and Drag Force Tester<\/strong>. Contact <strong>\u0160\u016bnu instrumenti<\/strong> today to learn more about how our advanced testing solutions can help you meet <strong>ISO 7864<\/strong> standards and improve your product performance.<\/p>","protected":false},"excerpt":{"rendered":"<p>The test for penetrability is a critical method used to evaluate the performance of needles in terms of their ability to penetrate various substrates. In industries like medical device manufacturing, packaging, and materials testing, understanding the force required for needle penetration can significantly impact product design and quality control. This article explores the needle penetration [&hellip;]<\/p>","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1478","post","type-post","status-publish","format-standard","hentry","category-softgel-test"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Test for Penetrability Needle Penetration Force and Drag Force Test with ISO 7864<\/title>\n<meta name=\"description\" content=\"Explore the test for penetrability and its importance in evaluating needle performance. Learn about the needle penetration force test, drag force test, and ISO 7864 standards for precise force measurement in substrate penetration.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.puncturetest.com\/lv\/drag-force-test\/\" \/>\n<meta property=\"og:locale\" content=\"lv_LV\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Test for Penetrability Needle Penetration Force and Drag Force Test with ISO 7864\" \/>\n<meta property=\"og:description\" content=\"Explore the test for penetrability and its importance in evaluating needle performance. Learn about the needle penetration force test, drag force test, and ISO 7864 standards for precise force measurement in substrate penetration.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.puncturetest.com\/lv\/drag-force-test\/\" \/>\n<meta property=\"og:site_name\" content=\"Puncture Test\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-23T07:47:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-23T07:47:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Editor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Editor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 min\u016btes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/\"},\"author\":{\"name\":\"Editor\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/person\/11d34f28ec5910cdc6daeb83206be0f7\"},\"headline\":\"Test for Penetrability: Understanding Needle Penetration Force and Drag Force Test Based on ISO 7864\",\"datePublished\":\"2026-03-23T07:47:16+00:00\",\"dateModified\":\"2026-03-23T07:47:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/\"},\"wordCount\":980,\"publisher\":{\"@id\":\"https:\/\/www.puncturetest.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp\",\"articleSection\":[\"Softgel Test\"],\"inLanguage\":\"lv-LV\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/\",\"url\":\"https:\/\/www.puncturetest.com\/drag-force-test\/\",\"name\":\"Test for Penetrability Needle Penetration Force and Drag Force Test with ISO 7864\",\"isPartOf\":{\"@id\":\"https:\/\/www.puncturetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp\",\"datePublished\":\"2026-03-23T07:47:16+00:00\",\"dateModified\":\"2026-03-23T07:47:17+00:00\",\"description\":\"Explore the test for penetrability and its importance in evaluating needle performance. Learn about the needle penetration force test, drag force test, and ISO 7864 standards for precise force measurement in substrate penetration.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/#breadcrumb\"},\"inLanguage\":\"lv-LV\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.puncturetest.com\/drag-force-test\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"lv-LV\",\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.puncturetest.com\/drag-force-test\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.puncturetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Test for Penetrability: Understanding Needle Penetration Force and Drag Force Test Based on ISO 7864\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.puncturetest.com\/#website\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"name\":\"Softgel Test\",\"description\":\"Puncture and Penetrabiity Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.puncturetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.puncturetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"lv-LV\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.puncturetest.com\/#organization\",\"name\":\"Softgel Test\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lv-LV\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"width\":836,\"height\":238,\"caption\":\"Softgel Test\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/person\/11d34f28ec5910cdc6daeb83206be0f7\",\"name\":\"Editor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"lv-LV\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/95df1d699cb620958de379e8fcffd6ab3f1693eafdfbb86ed0594de528b77bb0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/95df1d699cb620958de379e8fcffd6ab3f1693eafdfbb86ed0594de528b77bb0?s=96&d=mm&r=g\",\"caption\":\"Editor\"},\"url\":\"https:\/\/www.puncturetest.com\/lv\/author\/editor\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Test for Penetrability Needle Penetration Force and Drag Force Test with ISO 7864","description":"Explore the test for penetrability and its importance in evaluating needle performance. Learn about the needle penetration force test, drag force test, and ISO 7864 standards for precise force measurement in substrate penetration.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.puncturetest.com\/lv\/drag-force-test\/","og_locale":"lv_LV","og_type":"article","og_title":"Test for Penetrability Needle Penetration Force and Drag Force Test with ISO 7864","og_description":"Explore the test for penetrability and its importance in evaluating needle performance. Learn about the needle penetration force test, drag force test, and ISO 7864 standards for precise force measurement in substrate penetration.","og_url":"https:\/\/www.puncturetest.com\/lv\/drag-force-test\/","og_site_name":"Puncture Test","article_published_time":"2026-03-23T07:47:16+00:00","article_modified_time":"2026-03-23T07:47:17+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp","type":"image\/webp"}],"author":"Editor","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Editor","Est. reading time":"5 min\u016btes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.puncturetest.com\/drag-force-test\/#article","isPartOf":{"@id":"https:\/\/www.puncturetest.com\/drag-force-test\/"},"author":{"name":"Editor","@id":"https:\/\/www.puncturetest.com\/#\/schema\/person\/11d34f28ec5910cdc6daeb83206be0f7"},"headline":"Test for Penetrability: Understanding Needle Penetration Force and Drag Force Test Based on ISO 7864","datePublished":"2026-03-23T07:47:16+00:00","dateModified":"2026-03-23T07:47:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.puncturetest.com\/drag-force-test\/"},"wordCount":980,"publisher":{"@id":"https:\/\/www.puncturetest.com\/#organization"},"image":{"@id":"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage"},"thumbnailUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp","articleSection":["Softgel Test"],"inLanguage":"lv-LV"},{"@type":"WebPage","@id":"https:\/\/www.puncturetest.com\/drag-force-test\/","url":"https:\/\/www.puncturetest.com\/drag-force-test\/","name":"Test for Penetrability Needle Penetration Force and Drag Force Test with ISO 7864","isPartOf":{"@id":"https:\/\/www.puncturetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage"},"image":{"@id":"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage"},"thumbnailUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp","datePublished":"2026-03-23T07:47:16+00:00","dateModified":"2026-03-23T07:47:17+00:00","description":"Explore the test for penetrability and its importance in evaluating needle performance. Learn about the needle penetration force test, drag force test, and ISO 7864 standards for precise force measurement in substrate penetration.","breadcrumb":{"@id":"https:\/\/www.puncturetest.com\/drag-force-test\/#breadcrumb"},"inLanguage":"lv-LV","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.puncturetest.com\/drag-force-test\/"]}]},{"@type":"ImageObject","inLanguage":"lv-LV","@id":"https:\/\/www.puncturetest.com\/drag-force-test\/#primaryimage","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2026\/03\/Test-for-Penetrability-Needle-Penetration-Force-and-Drag-Force-Test-with-ISO-7864.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.puncturetest.com\/drag-force-test\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.puncturetest.com\/"},{"@type":"ListItem","position":2,"name":"Test for Penetrability: Understanding Needle Penetration Force and Drag Force Test Based on ISO 7864"}]},{"@type":"WebSite","@id":"https:\/\/www.puncturetest.com\/#website","url":"https:\/\/www.puncturetest.com\/","name":"Softgel tests","description":"Punkcijas un penetr\u0101cijas testa risin\u0101jumi","publisher":{"@id":"https:\/\/www.puncturetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.puncturetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"lv-LV"},{"@type":"Organization","@id":"https:\/\/www.puncturetest.com\/#organization","name":"Softgel tests","url":"https:\/\/www.puncturetest.com\/","logo":{"@type":"ImageObject","inLanguage":"lv-LV","@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","width":836,"height":238,"caption":"Softgel Test"},"image":{"@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.puncturetest.com\/#\/schema\/person\/11d34f28ec5910cdc6daeb83206be0f7","name":"Editor","image":{"@type":"ImageObject","inLanguage":"lv-LV","@id":"https:\/\/www.puncturetest.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/95df1d699cb620958de379e8fcffd6ab3f1693eafdfbb86ed0594de528b77bb0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/95df1d699cb620958de379e8fcffd6ab3f1693eafdfbb86ed0594de528b77bb0?s=96&d=mm&r=g","caption":"Editor"},"url":"https:\/\/www.puncturetest.com\/lv\/author\/editor\/"}]}},"_links":{"self":[{"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/posts\/1478","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/comments?post=1478"}],"version-history":[{"count":3,"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/posts\/1478\/revisions"}],"predecessor-version":[{"id":1482,"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/posts\/1478\/revisions\/1482"}],"wp:attachment":[{"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/media?parent=1478"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/categories?post=1478"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.puncturetest.com\/lv\/wp-json\/wp\/v2\/tags?post=1478"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}