{"id":1228,"date":"2025-06-24T11:24:43","date_gmt":"2025-06-24T03:24:43","guid":{"rendered":"https:\/\/www.puncturetest.com\/?page_id=1228"},"modified":"2025-07-03T15:43:22","modified_gmt":"2025-07-03T07:43:22","slug":"iso-11040-4","status":"publish","type":"page","link":"https:\/\/www.puncturetest.com\/pl\/standards\/iso-11040-4\/","title":{"rendered":"ISO 11040-4"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1228\" class=\"elementor elementor-1228\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c60fdbb e-flex e-con-boxed e-con e-parent\" data-id=\"c60fdbb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-db6fcba e-con-full e-flex e-con e-child\" data-id=\"db6fcba\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9d1f798 e-con-full e-flex e-con e-child\" data-id=\"9d1f798\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-8cc5a79 e-con-full e-flex e-con e-child\" data-id=\"8cc5a79\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6b67d4 elementor-widget elementor-widget-heading\" data-id=\"b6b67d4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4<br><small>Test penetracji ig\u0142\u0105<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69f526a elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"69f526a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"201\">Zapewnienie wydajno\u015bci i bezpiecze\u0144stwa wst\u0119pnie nape\u0142nionych strzykawek ma kluczowe znaczenie w zastosowaniach medycznych i farmaceutycznych. <strong data-start=\"521\" data-end=\"536\">ISO 11040-4<\/strong> przedstawia podstawowe specyfikacje dla <strong data-start=\"579\" data-end=\"667\">szklane beczki do wstrzykiwaczy i sterylizowane strzykawki gotowe do nape\u0142nienia<\/strong>. Jedn\u0105 z krytycznych ocen jako\u015bci w ramach tego standardu jest <strong data-start=\"736\" data-end=\"770\">Metoda testu penetracji ig\u0142\u0105<\/strong>kt\u00f3ry ocenia, jak \u0142atwo ig\u0142a strzykawki penetruje standardowy materia\u0142.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eff30d4 elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"eff30d4\" data-element_type=\"widget\" data-settings=\"{&quot;button_width&quot;:&quot;25&quot;,&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" action=\"\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"1228\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"eff30d4\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"Puncture Test\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tNazwa\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Nazwa\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-field_26b0101 elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-field_26b0101\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tFirma\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[field_26b0101]\" id=\"form-field-field_26b0101\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Firma\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tE-mail\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"E-mail\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label elementor-screen-only\">\n\t\t\t\t\t\t\t\tWiadomo\u015b\u0107\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Wiadomo\u015b\u0107\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-recaptcha elementor-field-group elementor-column elementor-field-group-field_50f0fd6 elementor-col-100\">\n\t\t\t\t\t<div class=\"elementor-field\" id=\"form-field-field_50f0fd6\"><div class=\"elementor-g-recaptcha\" data-sitekey=\"6LcO3HUrAAAAAKhAi3KjswdM4-_7i5zKd1s5FO2N\" data-type=\"v2_checkbox\" data-theme=\"light\" data-size=\"normal\"><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-25 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Wy\u015blij<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"pl\"\/><\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-163fe1b e-con-full e-flex e-con e-child\" data-id=\"163fe1b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f2b60d e-flex e-con-boxed e-con e-parent\" data-id=\"3f2b60d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c5f6d2 elementor-widget elementor-widget-heading\" data-id=\"7c5f6d2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Co to jest norma ISO 11040-4 i dlaczego ma znaczenie?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6126588 elementor-widget elementor-widget-text-editor\" data-id=\"6126588\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1111\" data-end=\"1465\"><strong data-start=\"1111\" data-end=\"1126\">ISO 11040-4<\/strong> to uznawany na ca\u0142ym \u015bwiecie standard z serii ISO 11040, kt\u00f3ry w szczeg\u00f3lno\u015bci dotyczy <strong data-start=\"1213\" data-end=\"1246\">szklane beczki do wstrzykiwaczy<\/strong> oraz <strong data-start=\"1251\" data-end=\"1288\">wst\u0119pnie zmontowane sterylizowane strzykawki<\/strong> przeznaczone do aseptycznego nape\u0142niania. Zapewnia, \u017ce komponenty te spe\u0142niaj\u0105 rygorystyczne kryteria wymiarowe i funkcjonalne w celu utrzymania sterylno\u015bci produktu, kompatybilno\u015bci i bezpiecze\u0144stwa pacjenta.<\/p><p data-start=\"1467\" data-end=\"1763\">Istotn\u0105 cz\u0119\u015bci\u0105 tego standardu jest <strong data-start=\"1510\" data-end=\"1537\">test penetracyjny ig\u0142y<\/strong>kt\u00f3ry weryfikuje <strong data-start=\"1558\" data-end=\"1584\">wydajno\u015b\u0107 mechaniczna<\/strong> ig\u0142y podczas u\u017cytkowania. \u0141atwo\u015b\u0107, z jak\u0105 ig\u0142a mo\u017ce przebi\u0107 pod\u0142o\u017ce, odzwierciedla jej w\u0142a\u015bciwo\u015bci. <strong data-start=\"1681\" data-end=\"1731\">ostro\u015b\u0107, jako\u015b\u0107 materia\u0142u, obr\u00f3bka powierzchni<\/strong>i sp\u00f3jno\u015b\u0107 produkcji.<\/p><p data-start=\"1765\" data-end=\"1794\">Testy te maj\u0105 kluczowe znaczenie dla:<\/p><ul><li data-start=\"1798\" data-end=\"1858\">Zapewnienie p\u0142ynnych wstrzykni\u0119\u0107 przy minimalnym dyskomforcie pacjenta<\/li><li data-start=\"1861\" data-end=\"1900\">Zapobieganie z\u0142amaniu lub wygi\u0119ciu ig\u0142y<\/li><li data-start=\"1903\" data-end=\"1956\">Gwarancja kompatybilno\u015bci z materia\u0142ami opakowaniowymi<\/li><li data-start=\"1959\" data-end=\"2008\">Potwierdzenie zgodno\u015bci w celu przed\u0142o\u017cenia do organ\u00f3w regulacyjnych<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-580df19 e-flex e-con-boxed e-con e-parent\" data-id=\"580df19\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8262e73 elementor-widget elementor-widget-heading\" data-id=\"8262e73\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wyja\u015bnienie metody testu penetracji ig\u0142\u0105<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c71437 elementor-widget elementor-widget-text-editor\" data-id=\"7c71437\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2061\" data-end=\"2365\">The <strong data-start=\"2065\" data-end=\"2099\">Metoda testu penetracji ig\u0142\u0105<\/strong>zgodnie z za\u0142\u0105cznikiem F do normy ISO 11040-4, ocenia <strong data-start=\"2153\" data-end=\"2222\">si\u0142a wymagana do przebicia okre\u015blonej folii testowej przez ig\u0142\u0119 strzykawki<\/strong>. Procedura ta wywodzi si\u0119 z normy DIN 13097-4 i jest wymieniona w dokumencie <a href=\"https:\/\/www.puncturetest.com\/pl\/standards\/iso-7864-needle-penetration-drag-force-test\/\"><strong data-start=\"2288\" data-end=\"2300\">ISO 7864<\/strong><\/a>Kolejna wa\u017cna norma dotycz\u0105ca sterylnych igie\u0142 podsk\u00f3rnych.<\/p><p data-start=\"2367\" data-end=\"2404\">Kluczowe elementy metody obejmuj\u0105:<\/p><ul><li data-start=\"2408\" data-end=\"2534\"><strong data-start=\"2408\" data-end=\"2426\">Aparatura testowa<\/strong>: A <strong data-start=\"2430\" data-end=\"2474\">Uniwersalny tester rozci\u0105gania i \u015bciskania<\/strong> z zakresem si\u0142y do 10 N i pr\u0119dko\u015bci\u0105 20-200 mm\/min.<\/li><li data-start=\"2537\" data-end=\"2612\"><strong data-start=\"2537\" data-end=\"2554\">Cz\u0119stotliwo\u015b\u0107 pr\u00f3bkowania<\/strong>: 500 Hz jest zalecane do dok\u0142adnego wykrywania si\u0142y szczytowej.<\/li><li data-start=\"2615\" data-end=\"2685\"><strong data-start=\"2615\" data-end=\"2632\">Uchwyt ig\u0142y<\/strong>: Zapewnia pionowe ustawienie w celu precyzyjnej penetracji.<\/li><li data-start=\"2688\" data-end=\"2779\"><strong data-start=\"2688\" data-end=\"2701\">Folia testowa<\/strong>: Materia\u0142 i grubo\u015b\u0107 musz\u0105 zosta\u0107 uzgodnione przez producenta i klienta.<\/li><li data-start=\"2782\" data-end=\"2861\"><strong data-start=\"2782\" data-end=\"2800\">Pr\u00f3bki igie\u0142<\/strong>: Mo\u017ce by\u0107 silikonowana lub nie, w zale\u017cno\u015bci od przeznaczenia.<\/li><li data-start=\"2864\" data-end=\"2992\"><strong data-start=\"2864\" data-end=\"2883\">Gromadzenie danych<\/strong>: A <strong data-start=\"2887\" data-end=\"2919\">krzywa si\u0142a vs. przemieszczenie<\/strong> jest generowany dla ka\u017cdego testu, mierz\u0105c <strong data-start=\"2958\" data-end=\"2972\">si\u0142a szczytowa<\/strong> oraz <strong data-start=\"2977\" data-end=\"2991\">si\u0142a oporu<\/strong>.<\/li><\/ul><p data-start=\"2994\" data-end=\"3141\">Metoda ta gwarantuje, \u017ce <strong data-start=\"3025\" data-end=\"3068\">Ostro\u015b\u0107 ig\u0142y i jednorodno\u015b\u0107 pow\u0142oki<\/strong> mieszcz\u0105 si\u0119 w dopuszczalnych parametrach, zapewniaj\u0105c niezawodne dzia\u0142anie strzykawki.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a9693b2 e-flex e-con-boxed e-con e-parent\" data-id=\"a9693b2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b44c843 elementor-widget elementor-widget-heading\" data-id=\"b44c843\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Najlepsze praktyki dotycz\u0105ce test\u00f3w strzykawkowych<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e38b53 elementor-widget elementor-widget-text-editor\" data-id=\"3e38b53\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3188\" data-end=\"3329\">Podczas przeprowadzania <strong data-start=\"3206\" data-end=\"3229\">test ig\u0142y strzykawkowej<\/strong>Niezb\u0119dne jest przestrzeganie wytycznych ISO przy jednoczesnej optymalizacji procesu pod k\u0105tem sp\u00f3jno\u015bci i dok\u0142adno\u015bci:<\/p><ol><li><strong data-start=\"3334\" data-end=\"3362\">U\u017cywanie zatwierdzonych substrat\u00f3w<\/strong>: Takich jak <strong data-start=\"3372\" data-end=\"3388\">guma lateksowa<\/strong>, <strong data-start=\"3390\" data-end=\"3406\">poliuretan<\/strong>lub <strong data-start=\"3411\" data-end=\"3427\">polietylen<\/strong> kt\u00f3re na\u015bladuj\u0105 stan sk\u00f3ry lub opakowania.<\/li><li><strong data-start=\"3472\" data-end=\"3507\">Kontrola zmiennych \u015brodowiskowych<\/strong>: Utrzymanie sp\u00f3jno\u015bci <strong data-start=\"3529\" data-end=\"3557\">temperatura i wilgotno\u015b\u0107<\/strong> podczas test\u00f3w.<\/li><li><strong data-start=\"3577\" data-end=\"3599\">Unikanie ponownego u\u017cycia pr\u00f3bki<\/strong>: Do ka\u017cdego testu nale\u017cy u\u017cy\u0107 nowego fragmentu folii lub pod\u0142o\u017ca.<\/li><li><strong data-start=\"3661\" data-end=\"3683\">Zapewnienie kalibracji<\/strong>: Maszyna testuj\u0105ca powinna by\u0107 regularnie kalibrowana przy u\u017cyciu identyfikowalnych standard\u00f3w.<\/li><li><strong data-start=\"3765\" data-end=\"3788\">Dok\u0142adnie dokumentuj<\/strong>: W raporcie z testu nale\u017cy uwzgl\u0119dni\u0107 specyfikacj\u0119 folii, pr\u0119dko\u015b\u0107 testu, liczb\u0119 pr\u00f3bek i wszystkie krzywe si\u0142y.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a6df764 e-flex e-con-boxed e-con e-parent\" data-id=\"a6df764\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15bd215 elementor-widget elementor-widget-heading\" data-id=\"15bd215\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.puncturetest.com\/pl\/tissue-paper-ball-burst-strength-test\/\">Sprz\u0119t do test\u00f3w penetracji ig\u0142\u0105 zapewniaj\u0105cy zgodno\u015b\u0107 z norm\u0105 ISO 11040-4<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e5f91e3 e-con-full e-flex e-con e-child\" data-id=\"e5f91e3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-44c6d75 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"44c6d75\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3963\" data-end=\"4156\">Dla laboratori\u00f3w i producent\u00f3w, kt\u00f3rzy musz\u0105 przeprowadza\u0107 testy penetracyjne igie\u0142 zgodnie z norm\u0105 ISO 11040-4, <strong data-start=\"4060\" data-end=\"4114\">Tester penetracji ig\u0142\u0105 NPT-01 firmy Cell Instruments<\/strong> to niezawodne rozwi\u0105zanie o wysokiej wydajno\u015bci.<\/p><p data-start=\"4158\" data-end=\"4197\">Kluczowe cechy <strong data-start=\"4178\" data-end=\"4188\">NPT-01<\/strong> obejmuj\u0105:<\/p><ul><li>Precyzyjne czujniki si\u0142y o dok\u0142adno\u015bci \u00b10,5%<\/li><li>Regulowane pr\u0119dko\u015bci testowania od 20 mm\/min do 200 mm\/min<\/li><li>Czas rzeczywisty <strong data-start=\"4320\" data-end=\"4349\">krzywe si\u0142a-przemieszczenie<\/strong> z mo\u017cliwo\u015bci\u0105 eksportu danych<\/li><li>Konfigurowalne uchwyty na ig\u0142y i zaciski foliowe<\/li><li>Kompatybilny z r\u00f3\u017cnymi rozmiarami strzykawek i \u015brednicami igie\u0142<\/li><\/ul><p data-start=\"4482\" data-end=\"4726\">Korzystanie z <strong data-start=\"4492\" data-end=\"4502\">NPT-01<\/strong> Usprawnia zgodno\u015b\u0107 z normami ISO 11040-4 i ISO 7864, jednocze\u015bnie zmniejszaj\u0105c zmienno\u015b\u0107 i zwi\u0119kszaj\u0105c integralno\u015b\u0107 danych. Szczeg\u00f3lnie dobrze nadaje si\u0119 do <strong data-start=\"4648\" data-end=\"4684\">Laboratoria badawczo-rozwojowe, dzia\u0142y kontroli jako\u015bci<\/strong>oraz <strong data-start=\"4690\" data-end=\"4725\">procesy walidacji regulacyjnej<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5f0632 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"e5f0632\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.puncturetest.com\/pl\/penetrability-tester-needle-penetration-test-method\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"400\" src=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\" class=\"attachment-full size-full wp-image-1230\" alt=\"ISO 11040-4 Metoda badania penetracji ig\u0142\u0105\" srcset=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp 500w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method-300x240.webp 300w, https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method-15x12.webp 15w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6821011 e-con-full e-flex e-con e-parent\" data-id=\"6821011\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-665057d elementor-cta--skin-classic elementor-animated-content elementor-bg-transform elementor-bg-transform-zoom-in elementor-widget elementor-widget-call-to-action\" data-id=\"665057d\" data-element_type=\"widget\" data-widget_type=\"call-to-action.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-cta\">\n\t\t\t\t\t<div class=\"elementor-cta__bg-wrapper\">\n\t\t\t\t<div class=\"elementor-cta__bg elementor-bg\" style=\"background-image: url(https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/02\/Elastomeric-Closures-Penetrability-Test-1024x256.webp);\" role=\"img\" aria-label=\"Test przenikalno\u015bci zamkni\u0119\u0107 elastomerowych\"><\/div>\n\t\t\t\t<div class=\"elementor-cta__bg-overlay\"><\/div>\n\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-cta__content\">\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h2 class=\"elementor-cta__title elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tZapewnij zgodno\u015b\u0107 igie\u0142 do strzykawek ju\u017c dzi\u015b\t\t\t\t\t<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__description elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tZrozumienie i stosowanie <b>Metoda testu penetracji ig\u0142y ISO 11040-4<\/b> ma kluczowe znaczenie dla ka\u017cdego producenta <b>ampu\u0142kostrzykawki lub ig\u0142y podsk\u00f3rne<\/b>. Standard zapewnia jasne wytyczne dotycz\u0105ce sprz\u0119tu, procedury testowej i raportowania w celu zapewnienia integralno\u015bci ig\u0142y i bezpiecze\u0144stwa pacjenta. Poprzez integracj\u0119 <b>niezawodny sprz\u0119t do testowania igie\u0142 strzykawkowych<\/b> jak <b>Puncturetest.com NPT-01<\/b>Firmy mog\u0105 usprawni\u0107 przestrzeganie przepis\u00f3w, zmniejszy\u0107 ryzyko i podnie\u015b\u0107 jako\u015b\u0107 produkt\u00f3w.\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__button-wrapper elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t<a class=\"elementor-cta__button elementor-button elementor-size-\" href=\"https:\/\/www.puncturetest.com\/pl\/contact\/\">\n\t\t\t\t\t\tKliknij tutaj\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 11040-4Needle Penetration Test Ensuring the performance and safety of prefilled syringes is vital in medical and pharmaceutical applications. ISO 11040-4 outlines the essential specifications for glass barrels for injectables and sterilized subassembled syringes ready for filling. One of the critical quality assessments under this standard is the needle penetration test method, which evaluates how [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"parent":974,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1228","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test<\/title>\n<meta name=\"description\" content=\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.puncturetest.com\/pl\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test\" \/>\n<meta property=\"og:description\" content=\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.puncturetest.com\/pl\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:site_name\" content=\"Puncture Test\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-03T07:43:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\",\"url\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\",\"name\":\"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test\",\"isPartOf\":{\"@id\":\"https:\/\/www.puncturetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\",\"datePublished\":\"2025-06-24T03:24:43+00:00\",\"dateModified\":\"2025-07-03T07:43:22+00:00\",\"description\":\"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.puncturetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Puncture Testing Standards\",\"item\":\"https:\/\/www.puncturetest.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 11040-4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.puncturetest.com\/#website\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"name\":\"Softgel Test\",\"description\":\"Puncture and Penetrabiity Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.puncturetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.puncturetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.puncturetest.com\/#organization\",\"name\":\"Softgel Test\",\"url\":\"https:\/\/www.puncturetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"contentUrl\":\"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"width\":836,\"height\":238,\"caption\":\"Softgel Test\"},\"image\":{\"@id\":\"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 11040-4 Metoda badania penetracji ig\u0142\u0105 - badanie ig\u0142\u0105 strzykawkow\u0105","description":"Metoda testowania penetracji ig\u0142y ISO 11040-4 za\u0142\u0105cznik F, testowanie ig\u0142y strzykawki i niezawodny sprz\u0119t testowy, taki jak NPT-01.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.puncturetest.com\/pl\/standards\/iso-11040-4\/","og_locale":"pl_PL","og_type":"article","og_title":"ISO 11040-4 Needle Penetration Test Method - Syringe Needle Test","og_description":"ISO 11040-4 Annex F needle penetration test method, syringe needle testing, and reliable test equipment like the NPT-01.","og_url":"https:\/\/www.puncturetest.com\/pl\/standards\/iso-11040-4\/","og_site_name":"Puncture Test","article_modified_time":"2025-07-03T07:43:22+00:00","og_image":[{"width":500,"height":400,"url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Szacowany czas czytania":"3 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/","url":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/","name":"ISO 11040-4 Metoda badania penetracji ig\u0142\u0105 - badanie ig\u0142\u0105 strzykawkow\u0105","isPartOf":{"@id":"https:\/\/www.puncturetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage"},"image":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage"},"thumbnailUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","datePublished":"2025-06-24T03:24:43+00:00","dateModified":"2025-07-03T07:43:22+00:00","description":"Metoda testowania penetracji ig\u0142y ISO 11040-4 za\u0142\u0105cznik F, testowanie ig\u0142y strzykawki i niezawodny sprz\u0119t testowy, taki jak NPT-01.","breadcrumb":{"@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#primaryimage","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/06\/ISO-11040-4-Needle-Penetration-Test-Method.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.puncturetest.com\/standards\/iso-11040-4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.puncturetest.com\/"},{"@type":"ListItem","position":2,"name":"Puncture Testing Standards","item":"https:\/\/www.puncturetest.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 11040-4"}]},{"@type":"WebSite","@id":"https:\/\/www.puncturetest.com\/#website","url":"https:\/\/www.puncturetest.com\/","name":"Test Softgel","description":"Rozwi\u0105zania do test\u00f3w przebicia i penetracji","publisher":{"@id":"https:\/\/www.puncturetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.puncturetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.puncturetest.com\/#organization","name":"Test Softgel","url":"https:\/\/www.puncturetest.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","contentUrl":"https:\/\/www.puncturetest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","width":836,"height":238,"caption":"Softgel Test"},"image":{"@id":"https:\/\/www.puncturetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/pages\/1228","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/comments?post=1228"}],"version-history":[{"count":5,"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/pages\/1228\/revisions"}],"predecessor-version":[{"id":1299,"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/pages\/1228\/revisions\/1299"}],"up":[{"embeddable":true,"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/pages\/974"}],"wp:attachment":[{"href":"https:\/\/www.puncturetest.com\/pl\/wp-json\/wp\/v2\/media?parent=1228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}